VHP: |
DT HS7: INVAL CONTRACT/STMNT CERT |
| ONLY A "Y" IS PERMITTED IN REC DT01, POS 36 TO INDICATE THE PRESENCE OF THE IMPORTERS SUBSTANTIATING STATEMENT/CONTRACT/OR MANUFACTURER'S CONFIRMATION LETTER. ANY OTHER CHARACTER WILL RESULT IN THIS ERROR MESSAGE. |
| THIS ERROR WILL OCCUR IF THE FILER TRIES TO PERFORM A DELETE OF A DRAWBACK CLAIM AND THE SYSTEM HAS NO RECORD OF THE CLAIM. BECAUSE THERE IS NO DATA IN THE SYSTEM, THERE IS NOTHING TO DELETE. |
|
VGE: |
FD 701: AFFRM/CMPLNCE NOT ON FILE |
| THE FDA AFFIRMATION OF COMPLIANCE (REC FD01, POS 20-22) MAY APPLY TO CERTAIN FDA LINES. IF USED, THE CODE MUST RESIDE IN THE FDA AFFIRMATIONS OF COMPLIANCE FILE OR THE ABOVE MESSAGE WILL RESULT. |
|
AB9: |
INVALID ACTIVITY CODE |
| THIS MESSAGE OCCURS WHEN THE DRAWBACK CLAIMANT'S BOND IS VALID, BUT IS FOR AN ACTIVITY CODE OTHER THAN 1A (DRAWBACK). OLD CODE 1A1 BONDS ARE NO LONGER ACCEPTABLE FOR DRAWBACK. |
| THIS ERROR MESSAGE IS GENERATED IN RESPONSE TO A BILL OF LADING UPDATE TRANSACTION (APPLICATION LN). IF THE L3 RECORD IS TRANSMITTED, AT A MINIMUM, THE BILL OF LADING (OR AIR WAYBILL) NUMBER IS REQUIRED, ALONG WITH THE MANIFESTED QUANTITY AND UNIT OF MEASURE. THE MANIFESTED QUANTITY MUST BE GREATER THAN ZERO. IF ZERO IS TRANSMITTED, THIS ERROR MESSAGE WILL BE GENERATED. IF EITHER THE MANIFEST QUANTITY OR UNIT OF MEASURE FIELDS ARE LEFT BLANK, ERROR MESSAGE 8VH WILL RESULT. NOTE: THE QUANTITY FIELD IN THE LN APPLICATION IS A NUMERIC FIELD AND MUST CONTAIN LEADING ZEROS. IF THE FIELD IS SPACE FILLED EXCEPT FOR THE ACTUAL QUANTITY, THIS REJECT MESSAGE WILL BE ISSUED. |
|
AP5: |
AFR REQUEST DATA REJECTED |
| FURTHER REVIEW CAN BE APPLIED FOR ONLY AT TIME OF INITIAL FILING OR BY MAKING AN AMENDMENT DURING ANY REMAINING PORTION OF THE 90 DAY PROTEST FILING PERIOD. THREE CRITERIA QUESTIONS MUST BE ANSWERED AND THE APPLICATION SUPPORTED BY A STATEMENT JUSTIFYING FURTHER REVIEW. EITHER THE 90 DAY PROTEST FILING PERIOD HAS EXPIRED OR ALL THE ELEMENTS FOR THE APPLICATION FOR FURTHER REVIEW HAVE NOT BEEN SUBMITTED. |
|
BL2: |
UNLAD DP CANNOT EQUAL ENTRY DP |
| IF AN IN-BOND NUMBER (EITHER CONVENTIONAL OR "V" NUMBER) IS SENT IN POSITIONS 3-14 OF THE 22 RECORD (EI) OR POSITIONS 3-14 OF THE HA RECORD (HI) THEN THE DISTRICT PORT OF UNLADING (POSITIONS 30-33 OF THE EI 20 RECORD OR POSITIONS 65-68 OF THE HI H1 RECORD) CANNOT BE THE SAME AS THE ENTRY DISTRICT PORT. |
|
VBN: |
FW 3-177: INVLD WILDLIFE DSCRIPTN |
| THE WILDLIFE DESCRIPTION (REC FW03, POS 24-27) MUST CONSIST OF FOUR ALPHA CHARACTERS AND MUST MATCH ONE OF THE WILDLIFE DESCRIPTION CODES LISTED IN THE CATAIR ON PAGE OGA-21. |
|
27G: |
*CENSUS* IMPROBABLE AIR TARIFF 1 |
| THIS MESSAGE IS ONE OF A NUMBER OF CENSUS WARNING MESSAGES. IN THIS CASE, THE MESSAGE INDICATES THAT THE TARIFF NUMBER (50 REC, POS 4-13) IS ONE THAT IS NOT USUALLY TRANSPORTED TO THE UNITED STATES BY AIR CARRIER. HEAVY MACHINERY, (EARTH MOVING EQUIPMENT), PETROLEUM PRODUCTS, ETC. ARE SOME EXAMPLES OF COMMODITIES WHOSE TARIFF NUMBER WILL GENERATE THIS WARNING MESSAGE. |
|
630: |
INVALID MODE OF TRANSPORTATION |
| IN ORDER FOR CARGO CERTIFICATION TO BE PERFORMED, THE MODE OF TRANSPORTATION (MOT) FIELD MUST BE COMPLETED. INFORMAL ENTRY SUMMARY TRANSACTIONS (APPLICATION IDENTIFIER EI) WHICH REQUEST CARGO CERTIFICATION, BUT DO NOT PROVIDE THE MOT IN THE 20 REC, POS 28-29, WILL RECEIVE THIS ERROR MESSAGE. SIMILARLY, SEPARATE CARGO RELEASE INPUT TRANSACTIONS (APPLICATION IDENTIFIER HI) WHICH OMIT THE MOT (H1 REC, POS 32-33) WILL ALSO RECEIVE THIS ERROR MESSAGE, WHETHER OR NOT THE RELEASE CERTIFICATION CODE (H1 REC, POS 34) IS ALSO TRANSMITTED. (INFORMAL ENTRY SUMMARY INPUT WHICH DOES NOT REQUEST CARGO CERTIFICATION WILL BE ACCEPTED WITHOUT THE MOT). |
| THIS MESSAGE OCCURS IN THE FDA INTERFACE, SPECIFICALLY IN THE 'SP' TRANSACTION. THIS IS WHERE FDA IS RESPONDING TO A FILER'S REQUEST TO ADD A DOMESTIC FIRM TO THE FEI FILE (FDA ESTABLISHMENT IDENTIFIER) AND IS RETURING TO ABI A 12 DIGIT NUMBER THAT IS ALREADY ON FILE. |
|
DKV: |
INVALID PETROLEUM INDICATOR |
| IN THE AUTOMATED DRAWBACK MODULE, THE 'D11' RECORD WILL CONTAIN A SPACE IF NOT A PETROLEUM CLAIM OR A '1' IF IT IS PETROLEUM. ANY OTHER INDICATORS GIVEN WILL CAUSE THIS ERROR. |
|
VDA: |
MPF SURCHARGE CANT BE > $3.00 |
| THIS MESSAGE RESULTS FROM AN ENTRY SUMMARY INPUT TRANSACTION (APPLICATION EI). FILERS IN TEST STATUS FOR CARGO RELEASE MUST INCLUDE AN MPF SURCHARGE AMOUNT OF $2.00 IF THE FILER IS NOT OPERATIONAL FOR CARGO RELEAES AT ANY OTHER PORT IN THE UNITED STATES. ABI WILL NOT ACCEPT A SURCHARGE AMOUNT GREATER THAN $3.00, IN ANY CASE. |
|
AP2: |
HEADER/DETAIL DATA REQUIRED |
| ONE OR MORE REQUIRED RECORDS IS MISSING. A P10 IS REQUIRED FOR INITIAL, AMENDMENT, ADDENDA, AND SERVICE REQUESTS. THE P11 IS REQUIRED FOR INITIAL FILING. THE P11 SHOULD BE USED AS PART OF THE AMENDMENT OR ADDENDA ONLY TO CHANGE A 'N' (NO) SAMPLE AND/OR 'N' (NO) HARDCOPY INDICATOR TO 'S' (SENT). THE P15 RECORD IS REQUIRED FOR INITIAL FILING. THE P16 RECORD IS REQUIRED WHEN FURTHER REVIEW IS REQUESTED IN THE ACCOMPANYING P10 OF THE INITIAL FILING OR AMENDMENT TRANSACTION. |
|
ASJ: |
PROTESTED ISSUE NOT APPLICABLE |
| THE P70 CANNOT BE REPEATED OR TRANSMITTED AS PART OF AN AMENDMENT, ADDENDA, SERVICE REQUEST. |
|
28M: |
DATA NOT DELETED IN TEST MODE |
| THIS ERROR MESSAGE OCCURS IN THE AII MODULE. THE DATA BASE IS UNAFFECTED BY A DATA TRANSMISSION BECAUSE THE SENDER'S STATUS WAS "TEST" FOR AII. |
|
VMA: |
HLO: SORT PARAMETER MUST BE A/U |
| THE SORT PARAMETER IS REQUIRED AND MUST BE A=ALL OR U=UNIQUE VALUES ONLY. |
|
1M9: |
IT DATE MORE THAN 2 YEARS OLD |
| THIS ERROR MESSAGE IS GENERATED IN RESPONSE TO AN AUTOMATED INVOICE TRANSACTION (APPLICATION CI). THE C11 AND C61 RECORDS PROVIDE SPACE IN WHICH TO REPORT THE CITY FOR THE PARTY IDENTIFIED IN THE C09 OR C59 RECORD. IF THE CITY FIELD IS TRANSMITTED WITH BLANKS, THIS ERROR MESSAGE WILL RESULT. FREQUENTLY, THIS ERROR WILL CAUSE ERROR MESSAGE EIK, "NAME/ADDRESS REQUIRED" TO BE GENERATED, AS WELL. |
|
AQM: |
FILING PERIOD BASE DATE REQR'D |
| WHEN THE ENTRY IS NOT LIQUIDATED, IS CANCELLED, OR IS SCHEDULED TO LIQUIDATE, BUT HAS NOT LIQUIDATED, OR IF ENTRY HAS BEEN DENIED, THE FILER LISTS ANOTHER DATE FROM WHICH THE FILING PERIOD IS CALCULATED. EXAMPLE: WHEN THE PROTEST IS FILED BY THE SURETY, THE SURETY HAS 90 DAYS FROM THE DATE OF NOTICE OF FIRST DEMAND FOR PAYMENT FROM CUSTOMS TO FILE THE PROTEST. |
|
AAI: |
MFR ID OR SHIPPER ID REQUIRED |
| A MANUFACTURER OR SUPPLIER CODE IDENTIFIES THE MANUFACTURER OR SUPPLIER. REFER TO CUSTOMS DIRECTIVE 3500-13, DATED NOVEMBER 24, 1986, FOR COMPLETE INSTRUCTIONS ON DETERMINING THE MANUFACTURER/SUPPLIER CODE. |
|
4JB: |
QUANTITY MUST BE NUMERIC |
| MUST BE EITHER NUMERIC OR BLANK. |
| THE DATE MUST BE NUMERIC, WITHOUT SLASHES OR HYPHENS, IN THE FORMAT MMDDYY. THE DATE WILL BE COMPARED WITH THE CURRENT SYSTEM DATE. IN MOST CASES THE DATE CANNOT BE GREATER THAN THE CURRENT SYSTEM DATE. DEPENDING UPON THE FUNCTION THE DATE MAY BE TOO FAR IN THE PAST, OR IT MAY BE OUT OF SEQUENCE WITH SOME OTHER DATE IN THE SYSTEM. FOR EXAMPLE, THE DATE OF ENTRY SUMMARY FILING MAY NOT PRECEDE THE DATE OF RELEASE ON AN IMMEDIATE RELEASE ENTRY. INBOND DATES MUST BE IN CHRONOLOGICAL ORDER. |
|
G9C: |
REMOTE ENTRY/ENTRY TYPE CONFLICT |
| IF THE B RECORD REMOTE ENTRY INDICATOR IS A '1',THE ENTRY TYPE CODE MUST BE EITHER 01 OR 11. |
|
VGM: |
FD 701: QTY IND;PREV QTY=0'S |
| UP TO SIX QUANTITIES CAN BE SENT IN THE FDA INTERFACE. IF ZEROS WERE TRANSMITTED IN A PRECEDING QUANTITY BLOCK AND A QUANTITY WAS TRANSMITTED IN THE INSTANT BLOCK, THIS ERROR MESSAGE RESULTS. FOR INSTANCE, IF ZEROS ARE TRANSMITTED IN THE UNIT 1 QUANTITY BLOCK OF REC FD02, POS 5-14 AND 0000000009 TRANSMITTED IN THE UNIT 2 QUANTITY BLOCK OF REC FD02, POS 19-28, THIS ERROR MESSAGE OCCURS. |